Blog Entry# 2916435
Posted: Dec 21 2017 (20:02)
6 Responses
Last Response: Dec 21 2017 (23:55)
Bumper Offlink Itarsi WAM-4-6P With 12565 Bihar Sampark Kranti SupperFast Express ЁЯШНЁЯШН
because 12566 ka wap-7 kal fail ho gaya tha .
20-Dec-17 12566 Dir 93 NER LJN 30247 GZB WAP7 3-Phase MOH, GZB, Aug 1 2016 / IB, GZB, Nov 17 2017 Harmonic filter
(NDLS-DBG/Load-24 Coaches),VCB opened with message "Harmonic filter current too high" and "TB-1 isolated". Put MCE off/on and worked but "Sparking from Harmonic filter". LP isolated traction bogie no.1 manually but same trouble occurred again, worked upto Gorakhpur (GKP) station with SR 40 kmph. Fresh loco given. MOH-01.08.16, IB-17.11.17, TI/NDLS-19.12.17, Major/Sec-Gonda-Gorakhpur (GD-GKP), Minor/Sec-Mankapur(MUR/NR) Time- 01.58-02.02 hrs at MUR, 02.17-02.21hrs at Lakhpatnagar(LKNR/NR) & 05.20-06.00 hrs at Gorakhpur(GKP)-. Loco with same train as dead...
more... to Samastipur(SPJ).